| TOCON系列-紫外線感測器(內建放大器) TOCON - UV 
										Sensors with Integrated Amplifier | 
									
										| The TOCON devices 
										are using modern hybrid technology to 
										cancel unwanted signal disturbances 
										caused by moisture or electromagnetic 
										radiation. The output voltage can be 
										directly connected to a controller or a 
										voltage multimeter. No external 
										amplifier is needed. Most of the TOCONs 
										are powered by a Silicon Carbide (SiC) 
										detector chip (ABC, A, B, E, C). The 
										BLUE and GAP series works with a GaP 
										chip. | 
									
										| 
											
												|  | Key Features |  
												| 
													SiC based UV hybride 
													detector with pre-amplifier 
													(0 - 5V output) 
													measures intensities 
													from 1.8 pW/cm2 
													up to 18 W/cm2 
													UV broadband, UVA, UVB, 
													UVC, Erythema or GaP-blue 
													light measurement 
													upgrade to M12x1 housing 
													with Hirschmann connector 
													available 
													our product 
													overview allows a simple 
													product selection  |  
												| Step 1: Selection of Spectral 
												Response |  
												| 
													UV-Broadband (ABC) 
													UVA (A) 
													UVB (B) 
													UVC (C) 
													UV-Index(Erythema) (E) 
													Blue light (BLUE) 
													Galliumphsophid (GaP) 
													 |  
												| Step 2: Selection of Sensitivity 
												Range |  
												| 
													"1”is very sensitive 
													and“10”is very unsensitive. 
													For detailed specification 
													please refer to Appendix B 
													(page 4) of the
													
													datasheet. 
													 |  | 
								
								
									
										|  | 
									
										| TOCON - UV 
										Broadband (SiC) | 
									
										| Model (PDF下載)
 | Approx. min. 
										irradiance | Approx. max. 
										irradiance (V_supply=5V) | Applications | 
									
										| TOCON_ABC1 (火焰偵測)
 | 1.8 pW/cm2 | 18 nW/cm2 | very low UV 
										radiation detection,
										
										flame detection. Replaces obsolete 
										UV10.SF and UV10.T2E. | 
									
										|  | 
									
										| TOCON_ABC2 | 18 pW/cm2 | 180 nW/cm2 | low UV 
										radiation detection, occupational safety | 
									
										|  | 
									
										| TOCON_ABC3 | 180 pW/cm2 | 1.8 μW/cm2 | low UV 
										radiation detection, occupational safety | 
									
										|  | 
									
										| TOCON_ABC4 | 1.8 nW/cm2 | 18 μW/cm2 | UV 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_ABC5 | 18 nW/cm2 | 180 μW/cm2 | UV 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_ABC6 | 180 nW/cm2 | 1.8 mW/cm2 | Optimized for 
										total sun UV measurements (not Erythema 
										curve) | 
									
										|  | 
									
										| TOCON_ABC7 | 1.8 μW/cm2 | 18 mW/cm2 | UV 
										irradiation measurement, industrial 
										standard UV radiation | 
									
										|  | 
									
										| TOCON_ABC8 | 18 μW/cm2 | 180 mW/cm2 | Curing lamp 
										control | 
									
										|  | 
									
										| TOCON_ABC9 | 180 μW/cm2 | 1.8 W/cm2 | Curing lamp 
										control | 
									
										|  | 
									
										| TOCON_ABC10 | 1.8 mW/cm2 | 18 W/cm2 | UV hardening 
										control and other very high radiation 
										sources | 
								
								
									
										|  | 
									
										| TOCON - UVA 
										(SiC) *請注意:型號下括弧內為舊型號,2014/3/31開始使用新型號
 | 
									
										| Model (Datasheet)
 | Approx. min. 
										irradiance | Approx. max. 
										irradiance (V_supply=15V) | Applications | 
									
										| TOCON_A4 (TOCON_A3)
 | 1.8 nW/cm2 | 18 μW/cm2 | UVA radiation 
										detection | 
									
										|  | 
									
										| TOCON_A5 (TOCON_A4)
 | 18 nW/cm2 | 180 μW/cm2 | UVA 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_A6 (TOCON_A5)
 | 180 nW/cm2 | 1.8 mW/cm2 | UVA 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_A7 (TOCON_A6)
 | 1.8 μW/cm2 | 18 mW/cm2 | UVA 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_A8 (TOCON_A7)
 | 18 μW/cm2 | 180 mW/cm2 | Measurement 
										of high UVA irradiation, curing lamp 
										control | 
									
										|  | 
									
										| TOCON_A9 (TOCON_A8)
 | 180 μW/cm2 | 1.8 W/cm2 | Measurement 
										of very high UVA irradiation, curing 
										lamp control | 
									
										|  | 
									
										| TOCON_A10 (TOCON_A9)
 | 1.8 mW/cm2 | 18 W/cm2 | Measurement 
										of very high UVA irradiation, curing 
										lamp control | 
								
								
									
										|  | 
									
										| TOCON - UVB 
										(SiC) *請注意:型號下括弧內為舊型號,2014/3/31開始使用新型號
 | 
									
										| Model 
										(Datasheet) | Approx. max. 
										irradiance | Applications | 
									
										| TOCON_B4 (TOCON_B1)
 | 7.5 μW/cm2 | UVB 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_B5 (TOCON_B2)
 | 75 μW/cm2 | UVB 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_B6 (TOCON_B3)
 | 0.75 mW/cm2 | UVB 
										irradiation measurement | 
								
								
									
										|  | 
									
										| TOCON - UVC 
										(SiC) | 
									
										| Model (Datasheet)
 | Approx. min. 
										irradiance | Approx. max. 
										irradiance (V_supply=15V)
 | Applications | 
									
										| TOCON_C2 | 18 pW/cm2 | 180 nW/cm2 | low UVC 
										radiation detection, occupational safety | 
									
										|  | 
									
										| TOCON_C3 | 180 pW/cm2 | 1.8 μW/cm2 | UVC radiation 
										detection, occupational safety | 
									
										|  | 
									
										| TOCON_C4 | 1.8 nW/cm2 | 18 μW/cm2 | UVC 
										irradiation measurement | 
									
										|  | 
									
										| TOCON_C5 | 18 nW/cm2 | 180 μW/cm2 | Purification 
										lamp control | 
									
										|  | 
									
										| TOCON_C6 | 180 nW/cm2 | 1.8 mW/cm2 | Purification 
										lamp control | 
									
										|  | 
									
										| TOCON_C7 | 1.8 μW/cm2 | 18 mW/cm2 | Purification 
										lamp control | 
									
										|  | 
									
										| TOCON_C8 | 18 μW/cm2 | 180 mW/cm2 | Curing lamp 
										control | 
									
										|  | 
									
										| TOCON_C9 | 180 μW/cm2 | 1.8 W/cm2 | Curing lamp 
										control | 
								
								
									
										|  | 
									
										| TOCON - UV-Index 
										(Erythema) (SiC) | 
									
										| Model 
										(Datasheet) | Approx. max. 
										irradiance | Applications | 
									
										| TOCON_E1 | 3 UVI | UV-Index 
										measurements (this device needs sunlight 
										attenuator) | 
									
										|  | 
									
										| TOCON_E2 | 30 UVI | UV-Index 
										measurements | 
									
										|  | 
								
								
									
										|  | 
									
										| TOCON - Blue 
										Light (GaP) *請注意:型號下括弧內為舊型號,2014/3/31開始使用新型號
 | 
									
										| Model (Datasheet)
 | Approx. min. 
										irradiance | Approx. max. 
										irradiance (V_supply=15V) | Applications | 
									
										| TOCON_blue4 (TOCON_blue1)
 | 4.2 nW/cm2 | 43 μW/cm2 | Measurement 
										of very low blue light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_blue5 (TOCON_blue2)
 | 42 nW/cm2 | 430 μW/cm2 | Measurement 
										of low blue light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_blue6 (TOCON_blue3)
 | 420 nW/cm2 | 4.3 mW/cm2 | Measurement 
										of blue light irradiation, occupational 
										safety | 
									
										|  | 
									
										| TOCON_blue7 (TOCON_blue4)
 | 4.2 μW/cm2 | 43 mW/cm2 | Measurement 
										of blue light irradiation, occupational 
										safety | 
									
										|  | 
									
										| TOCON_blue8 (TOCON_blue5)
 | 42 μW/cm2 | 430 mW/cm2 | Measurement 
										of high blue light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_blue9 (TOCON_blue6)
 | 420 μW/cm2 | 4.3 W/cm2 | Measurement 
										of very high blue light irradiation, 
										occupational safety | 
								
								
									
										|  | 
									
										| TOCON - UV+VIS 
										(GaP) *請注意:型號下括弧內為舊型號,2014/3/31開始使用新型號
 | 
									
										| Model (Datasheet)
 | Approx. min. 
										irradiance | Approx. max. 
										irradiance (V_supply=15V) | Applications | 
									
										| TOCON_GaP4 (TOCON_GaP1)
 | 4.2 nW/cm2 | 43 μW/cm2 | Measurement 
										of very low UV & VIS light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_GaP5 (TOCON_GaP2)
 | 42 nW/cm2 | 430 μW/cm2 | Measurement 
										of low UV & VIS light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_GaP6 (TOCON_GaP3)
 | 420 nW/cm2 | 4.3 mW/cm2 | Measurement 
										of UV & VIS light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_GaP7 (TOCON_GaP4)
 | 4.2 μW/cm2 | 43 mW/cm2 | Measurement 
										of UV & VIS light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_GaP8 (TOCON_GaP5)
 | 42 μW/cm2 | 430 mW/cm2 | Measurement 
										of high UV & VIS light irradiation, 
										occupational safety | 
									
										|  | 
									
										| TOCON_GaP9 (TOCON_GaP6)
 | 420 μW/cm2 | 4.3 W/cm2 | Measurement 
										of very high UV & VIS light irradiation, 
										occupational safety | 
								
								
									
										|  | 
									
										| TOCON Housing 
										(Optional) | 
									
										| Model 
										(Datasheet) | Properties | 
									
										| TOCON_steel_housing | M12x1 thread, 
										32 mm length, integrated sensor 
										connector, price incl. 2 m plug cable. | 
									
										|  | 
									
										| TOCON_PTFE_housing | M12x1 thread, 
										material teflon (PTFE), 31 mm length, 
										integrated sensor connector, price incl. 
										2 m plug cable. | 
									
										|  | 
									
										| TOCON_starter_kit | Kit for 
										initial testing setup, includes a TOCON 
										socket, two banana plugs to connecct 
										with a voltmeter and a 9V block battery |