ultrasonic switch:
															
															
															
															
															
															
															click here to 
															enlarge schematic
															
															
															
															
															parts:
															 
															 
															
																
																	| 
																	
																	
																	Transmitter 
																	Parts: | 
																
																	| 
																	
																	IC1 | 
																	
																	NE555 timer 
																	IC | 
																
																	| 
																	
																	VR1 | 
																	
																	10k variable 
																	resistor | 
																
																	| 
																	
																	R1 | 
																	
																	4.7k 
																	resistor | 
																
																	| 
																	
																	R2 | 
																	
																	18k 
																	potentiometer | 
																
																	| 
																	
																	R3 | 
																	
																	1k resistor | 
																
																	| 
																	
																	R4, R5 | 
																	
																	220 ohm 
																	resistor | 
																
																	| 
																	
																	C1 | 
																	
																	680 
																	picofarad 
																	capacitor | 
																
																	| 
																	
																	C2 | 
																	
																	0.01uf 
																	capacitor | 
																
																	| 
																	
																	D1, D2 | 
																	
																	1N4148 Diode | 
																
																	| 
																	
																	T1 | 
																	
																	SL100 NPN 
																	transistor | 
																
																	| 
																	
																	T2 | 
																	
																	SK100 PNP 
																	transistor | 
																
																	| 
																	
																	S1 | 
																	
																	SPST 
																	momentary 
																	contact 
																	switch | 
																
																	| 
																	
																	XMTR | 
																	
																	ultrasonic 
																	transmitter 
																	40-50khz | 
															
															
																 
															
															
															 
															 
															
																
																	| 
																	
																	
																	Receiver 
																	Parts: | 
																
																	| 
																	
																	RCVR | 
																	
																	Ultrasonic 
																	Receiver 
																	40-50khz | 
																
																	| 
																	
																	RL1 | 
																	
																	6volt 200ohm 
																	resistor | 
																
																	| 
																	
																	IC2 | 
																	
																	CA3140 | 
																
																	| 
																	
																	VR2 | 
																	
																	250k 
																	Variable 
																	Resistor | 
																
																	| 
																	
																	R6 | 
																	
																	390k 
																	Resistor | 
																
																	| 
																	
																	R7 | 
																	
																	470k 
																	Resistor | 
																
																	| 
																	
																	R8, R12 | 
																	
																	15k Resistor | 
																
																	| 
																	
																	R9 | 
																	
																	12k | 
																
																	| 
																	
																	R10, R13 | 
																	
																	10k | 
																
																	| 
																	
																	R11 | 
																	
																	4.7k | 
																
																	| 
																	
																	R14 | 
																	
																	100k 
																	Resistor | 
																
																	| 
																	
																	R15 | 
																	
																	33 ohm 
																	Resistor | 
																
																	| 
																	
																	C3 | 
																	
																	0.22uf 
																	ceramic 
																	capacitor | 
																
																	| 
																	
																	C4 | 
																	
																	0.1uf 
																	ceramic 
																	capacitor | 
																
																	| 
																	
																	C5 | 
																	
																	560n ceramic 
																	capacitor | 
																
																	| 
																	
																	T3,T4 | 
																	
																	BC548 NPN 
																	Transistor | 
																
																	| 
																	
																	T5 | 
																	
																	BC558 PNP 
																	Transistor | 
																
																	| 
																	
																	T6 | 
																	
																	SL100 NPN 
																	Transistor | 
																
																	| 
																	
																	D3,D4,D5 | 
																	
																	1N4148 Diode | 
															
															
																 
															
															
															
															all resistors are 5 
															or 10 percent 
															tolerance, 1/4-watt
															all capacitors are 
															10 percent 
															tolerance,
															rated 35 volts or 
															higher 
															
															
															The circuit 
															described generates 
															(transmits) 
															ultrasonic sound of 
															frequency between 40 
															and 50 kHz. As with 
															any other remote 
															control system this 
															cirucit comprises of 
															a mini transmitter 
															and a receiver 
															circuit. Transmitter 
															generates ultrasonic 
															sound and the 
															receiver senses 
															ultrasonic sound 
															from the transmitter 
															and switches on a 
															relay.
															
															The ultrasonic 
															transmitter uses a 
															555 based astable 
															multivibrator. It 
															oscillates at a 
															frequency of 40-50 
															kHz. An ultrasonic 
															transmitter 
															transducer is used 
															here to transmit 
															ultrasonic sound 
															very effectively. 
															The transmitter is 
															powered from a 
															9-volt PP3 single 
															cell. The ultrasonic 
															receiver circuit 
															uses an ultrasonic 
															receiver transducer 
															to sense ultrasonic 
															signals. It also 
															uses a two-stage 
															amplifier, a 
															rectifier stage, and 
															an operational 
															amplifier in 
															inverting mode. 
															Output of op-amp is 
															connected to a relay 
															through a 
															complimentary relay 
															driver stage. A 
															9-volt battery 
															eliminator can be 
															used for receiver 
															circuit, if 
															required. When 
															switch S1 of 
															transmitter is 
															pressed, it 
															generates ultrasonic 
															sound. The sound is 
															received by 
															ultrasonic receiver 
															transducer. It 
															converts it to 
															electrical 
															variations of the 
															same frequency. 
															These signals are 
															amplified by 
															transistors T3 and 
															T4. The amplified 
															signals are then 
															rectified and 
															filtered. The 
															filtered DC voltage 
															is given to 
															inverting pin of 
															op-amp IC2. The non- 
															inverting pin of IC2 
															is connected to a 
															variable DC voltage 
															via preset VR2 which 
															determines the 
															threshold value of 
															ultrasonic signal 
															received by receiver 
															for operation of 
															relay RL1. The 
															inverted output of 
															IC2 is used to bias 
															transistor T5. When 
															transistor T5 
															conducts, it 
															supplies base bias 
															to transistor T6. 
															When transistor T6 
															conducts, it 
															actuates the relay. 
															The relay can be 
															used to control any 
															electrical or 
															electronic 
															equipment.
															Important hints:
															1. Frequency of 
															ultrasonic sound 
															generated can be 
															varied from 40 to 50 
															kHz range by 
															adjusting VR1. 
															Adjust it for 
															maximum performance.
															2. Ultrasonic sounds 
															are highly 
															directional. So when 
															you are operating 
															the switch the 
															ultrasonic 
															transmitter 
															transducer of 
															transmitter should 
															be placed towards 
															ultrasonic receiver 
															transducer of 
															receiver circuit for 
															proper functioning.
															3. Use a 9-volt PP3 
															battery for 
															transmitter. The 
															receiver can be 
															powered from a 
															battery eliminator 
															and is always kept 
															in switched on 
															position.
															4. For latch 
															facility use a DPDT 
															relay if you want to 
															switch on and switch 
															off the load. A 
															flip-flop can be 
															inserted between IC2 
															and relay. If you 
															want only an 
															?ON-time delay? use 
															a 555 only at output 
															of IC2. The relay 
															will be energised 
															for the required 
															period determined by 
															the timing 
															components of 555 
															monostable 
															multivibrator.
															5. Ultrasonic waves 
															are emitted by many 
															natural sources. 
															Therefore, 
															sometimes, the 
															circuit might get 
															falsely triggered, 
															espically when a 
															flip-flop is used 
															with the circuit, 
															and there is no 
															remedy for that.